Air Conditioning Design

Brad & Marie Fittler...

...wanted flexibility to operate all areas or individual rooms.

The twin digital inverter air conditioner handles this with ease.

The Air Conditioning System Design

Brad & Marie Fittler's Home

This beautifully renovated attached semi, located in the eastern suburbs,
presented a large air conditioning design challenge to the Penrith Air design team.

Owned by Sydney Rugby League legend  Brad Fittler and his wife Marie,
this renovated semi came from less auspicious beginnings.

With amazing vision and a passion for design, Brad and Marie removed more than 1500 tonnes of sandstone from the existing site to create a huge entertainment area with double garage. View Rear Elevation

The concrete roof of this area is very cleverly filled with soil and turfed to create a yard (View Backyard) leading from the ground floor sun- room. View Ground Floor Top View with Garage

The Air Conditioning System Design

The air conditioning project evolved with many on-site changes during construction. However, the decision to rake the upstairs ceilings left limited options for traditional ducted air conditioning.

Fortunately, the Carrier/Toshiba Super Modular Multi System (SMMS) air conditioner provided the perfect solution for this air conditioning project.

The SMMS air conditioner allows a selection of 13 different styles of indoor units all connected to a single, twin digital inverter outdoor condenser.

View Toshiba Brochure PDF File Size: 1.5Mb
Visit Toshiba Website Air Conditioner - Toshiba Super Modular Multi System
You may need to download the free Adobe reader here to view these PDF files. Adobe Reader Download

The design for this air conditioning project incorporated a single 10HP, 28kW outdoor condenser, serving 6 individual indoor fan coil units, each with individual thermostats allowing seperate temperature control for each unit.

The indoor areas are served by:-

 

Indoor Area

 

Air Conditioning Unit

Sun Room 8kW  ceiling recessed cassette
Living Room, Kitchen 8kW ceiling recessed  cassette
Study, Guest Bedroom 6kW low static ducted under  floor
Bedroom 3  2.5kW  bulkhead unit
Bedroom 2  2.5kW  bulkhead unit
Bedroom 1, Family Room 8kW high static  ducted unit above bathroom

 

Dynamic and Schematic Views of Project Work

Dynamic View Static PDF View
First Floor Ducted Top View First Floor Ducted Top View
First Floor Elevation First Floor Elevation View
Ground Floor Top Elevation Ground Floor Top Elevation View
Rear Elevation View View Toshiba SMMS Schematic